1785 slot on drive array not configured no drives detected

Compaq ProLiant 1500 and Debian 2.2 ("Potato") 178-Processor Configuration Invalid 172-EISA Configuration Nonvolatile Memory Invalid Initialization Aborted 172-1 Configuration Nonvolatile Memory Invalid Slot 6 Drive Array Initializing 1785-Slot 6 Drive Array not Configured 162-System Options Not Set SCSI Device Detected - System Board, SCSI ID 5: COMPAQ CD-ROM CR-503BCQ SCSI Device Detected

SOLVED: Run Compaq Array Configuration Utility - Fixya So i made some changes and it wanted a reboot so i re booted the server. Now when the server boots get i message "1785-slot 7 drive array not configured. Run compaq array configuration utility" if i press F1 to ignore and continue it says no boot disk and if i try install sever 2003 from the cd it does not find the disks. 1079926 - HP Log on bugzilla8.db.scl3.mozilla.com is WARNING ... HP Log on bugzilla8.db.scl3.mozilla.com is WARNING: WARNING 0001: POST Error: 1785-Slot X Drive Array Not Configured--- RESOLVED FIXED ... HPE Smart Storage for HPE ProLiant Gen9 Servers technical ...

HP DL380 G6 Smart Array P410i No Drives Detected

1785-slot 0 drive array not configured - Comunidad de ... 1785-slot 0 drive array not configured. el ‎23-03-2017 12:52 PM. No mi amigo te comneto que ya habia probado esa opcion, pero no se habilita. Adicional la pantalla que me muestra el server es distinta. Me descargue el Intelligent Provisioning desde la pagina de HP, pero sigo con el mismo problema. 0 kudos Repair Hp Blade Post Error 1785-drive Array Not Configured ... Figure 05: During POST, Smart -> Embedded Storage -> Dynamic Smart Array B140i and press Enter. Figure 01 Shows "1785-Slot 0b Drive Array Not Configured No 1785 Slot 0 Drive Array Not Configured No Drives Detected Look in the System Management Homepage and Array Configuration Utility and checked my arrays. [SOLVED] RAID issue with HP P410 and disks in wrong order ... RAID issue with HP P410 and disks in wrong order. by Wars. on ... 1785 - Slot 4 Drive Array Not Configured. Drive positions appear to have been changed. Run Array Diagnostics Utility (ADU) if previous positions are unknown. ... I've removed them and gone into the raid configuration via F8 and it says there's no logical drives, nothing in there ...

I had this question after viewing How to diagnose/replace RAID drive HP Proliant Smart Array. Just purchased an older HP DL380 G6 server, purchased new drives but won't recognize any of the drives... HP DL380 G6 Smart Array P410i No Drives Detected

Figure 05: During POST, Smart -> Embedded Storage -> Dynamic Smart Array B140i and press Enter. Figure 01 Shows "1785-Slot 0b Drive Array Not Configured No 1785 Slot 0 Drive Array Not Configured No Drives Detected Look in the System Management Homepage and Array Configuration Utility and checked my arrays. How to configure a hard drive with SSA on a Proliant ... How do I use SSA to configure a hard drive on a ProLiant ML30 Gen9 server? I hooked up the harddrive to the 4x cable, plugged that into the appropriate slot on the harddrive, then used an ISO to install Fedora. ... 1785-Slot 0b Drive Array Not Configured. Action: Use the SSA to configure the attached drives. But I don't know how to go about ... 1785-slot 0 drive - DylanWelsh3's blog TIME: 4.02.2012 Author: quilummay 1785-slot 0 drive troublesshooting dl380 g4 - Scribd If the CD-ROM drive jumpers are set to CS (the factory default), be sure the CD-ROM drive is installed as device 0 on the cable so that it is in position for the server. HP PROLIGHT SERVER TROUBLESHOOTING MANUAL Pdf Download. Be sure all drives are fully seated. Replace defective cables, drive X, or both. 1785-Slot X Drive Array Not Configured... (followed by one of the following): ...(1) Run Array Configuration Utility (2) No drives detected (3) Drive positions appear to have changed – Run Drive Array Advanced Diagnostics if previous positions are unknown.

Slot 1 Drive Array Not Configured (Дисковый массив на слоте 1 не настроен) К возникновению этой ошибки приводит много различных неисправностей, поэтому, прежде чем что-либо предпринять, необходимо проверить наличие каждой из нижеприведенных неисправностей. •

...Drive Detected 1794-Slot 3 Drive Arraye - Array Accelerator Battery Charge low Array Accelerator Posted-Write Cacheor CD-ROM Drive(s) Detected: SCSI Port 2: SCSI ID 1 1785-Slot 3 Drive Arraye Not Configured No Drives Detected ... 1785 drive array not configured no drives detected HP… 1785 drive array not configured no drives detected HP ProLiant DL360E GEN 8. 1785 Drive Array Not Configured

I had this question after viewing How to diagnose/replace RAID drive HP Proliant Smart Array. Just purchased an older HP DL380 G6 server, purchased new drives but won't recognize any of the drives... HP DL380 G6 Smart Array P410i No Drives Detected

айло с исо-образа, который у меня на ноуте. на сервере вот такое есть: Latest Integrated Management Log Entry: POST Error: 1785-Drive Array not Configured. iLO Firmware Version: 1.50. Drive array configuration not saved - Help needed! -… I'm having troubles configuring my drive arrays in HP Intelligent Provisioning since I reset my server configuration. I have the latest version of IPThen, after exiting IP and rebooting, during POST I can see my arrays in iLO, but during POST I get the message " 1785-Drive array not configured" and...

asciidoc-odf/rear-documentation.asciidoc at master ... iLO 2 v1.78 Jun 10 2009 10.5.20.171 Slot 0 HP Smart Array P410i Controller (512MB, v2.00) 1 Logical Drive Slot 3 HP Smart Array P401 Controller (512MB, v2.00) 1 Logical Drive Slot 4 HP Smart Array P212 Controller (0MB, v2.00) 0 Logical Drives Tape or CD-ROM Drive(s) Detected: Port 1I: Box 0: Bay 4 1785-Slot 4 Drive Array Not Configured No ... Perform hot plug removal and reinstallation hot plug hard ...